Click To Chat
Register ID Online
Login [Online Reload System]



Intensifier pump vs direct drive

intensifier pump vs direct drive A device connected to a fire alarm system not required by the fire alarm standard but may be required by other standards, e. 014" Details. A wide variety of product lineup is available for various kinds of operation. The Sundyne diffuser design allows for continuous duty at the design flow and at low flows, and Apr 20, 2021 · Direct Drive Vs Magnetic Drive Pumps Pricing or direct and effluent pumps vs those required performance characteristics which is encapsulat -Watch the Direct Drive Washer Repair Videos!-Buy A Washing Machine Motor!-Not SureYet I Need More Help. By analyzing the combined effects of cutting performance, fatigue life, and pump efficiencies, operating with higher flow rates is economically more Oct 05, 2015 · The direct drive air compressor is an oil-free solution, which makes it ideal for occasional and home projects. Sometimes called a triplex pump, the electric motor rotates a crank with three pistons to generate the ultrahigh-pressure water. This means direct drive requires more current from the car’s battery, larger battery cables are needed and other components are designed to handle higher current. The Matrix-50 intensifier pump is designed for water cutting requiring a continuous output pressure of 60,000 PSI and is available in a 50 HP model. Jan 19, 2021 · Motors, Drives Direct drive vs. offers what the company says is increased efficiency, improved reliability and lower operating costs by delivering more JetPower at the nozzle, equal to today's 135 hp intensifier designs. Neptune’s JD Series is engineered to meet the needs of a large direct drive mixer with a housing that cannot leak oil. FUNDAMENTAL DIFFERENCES IN THE OPERATION: • Intensifiers stroke at less than 60 strokes per minute. Annunciator. Before we start looking at these two pumps May 18, 2016 · To drive 42. Small Bench Top Air Driven Homogenizer MFIC. The pump is a simple, off-the-shelf submersible pump (sub-pump), electrically powered via a RCD-protected supply cable and triggered by a float switch. All pump power ratings are based on the electrical consumption of the pump, not the output power of the pump. In both pump designs if you increase the available operating horsepower you will increase the volume of water output at the given pressure and that itself, can Jan 31, 2012 · A waterjet cutting solution uses two types of pumps: Hydraulic Intensifier vs. Such a machine may be constructed by mechanically connecting two pistons, each working in a separate cylinder of a different diameter. Features. There are two basic types of waterjet pumps, direct drive pumps (also known as positive displacement or crank pumps) and hydraulic intensifier pumps. Direct drive pumps cost less Direct Drive Pumps vs. ZPI-400785 Pneudraulic Intensifiers. At Express Compressors, we can help you find the best air compressor for your specific needs. While each type is a viable option for mounting a hydraulic pump, it is important to understand each type of mount to ensure an effective connection is made between the PTO and pump. Aug 21, 2017 · A hydraulic pump for mobile applications, like the gear, piston or vane pump, can be either direct mounted to the PTO or remote mounted – using a driveline. Remove the cabinet and jumper the lid switch (tan to gray). . Efficiency beats pressure: Direct drive crankshaft pumps are inherently more efficient in converting motor power to nozzle power because they do not suffer from the hydraulic losses of an intensifier pump. The Direct Drive, which also comes as an upgraded dual channel model, gives you ringing, vintage-sounding tones that separate each note with impressive clarity. The pulley system allows these pumps to turn at a much lower RPM than a direct drive pump (typically 900-1400 RPM). This model hits a higher price point at $1,149 MSRP in white but has the features package to back it up. Motor splines directly into shaft eliminating and shear pins and or clutches. Direct drive pumps are filled with a non-toxic oil that if it leaks into the pond is not a safety concern but is disturbing to consumers. All of our standard direct drive and pulley drive pumps are designed and built with UL recognized components and include thermal and short circuit DIRECTORR® DIRECT-DRIVE VACUUM PUMP MODELS: 8905 8907 8912 8917 8920 8925 Gardner Denver Welch Vacuum Technology, Inc. INTENSIFIER VS. An Object In The Washing Machine Drain Pump. 5 horsepower to the nozzle, the OMAX pump needs a 50 horsepower electric motor, while the intensifier pump needs 70 horsepower. The work duty of a vacuum pump can vary between intermittent use and running continuously. This is a compact direct-drive triplex [three plunger rods] plunger pump, featuring a brass manifold, easy-to-service 304SS stacked valve assemblies, solid ceramic plungers and standard NBR [Buna-N] seals and o-rings. High Power HP Homogenizer Intensifier Blue Diamonds custom made direct drive: Uses a 3. Maintenance is a significant cost to any operation. Routine maintenance can add up and downtime can really cut into your bottom line. Waterjet Cutting Machine. Mar 20, 2019 · Upon the closing of the transaction, expected on or around April 9, OMAX’s industry leading direct drive pumps, software, and applications technologies will combine with Hypertherm’s complementary portfolio of intensifier-based pumps and abrasive recycling systems, to form the industry’s leading waterjet technology offering. Intensifier pumps were considered easier and cheaper to maintain, especially at high pressures, while direct-drive systems offered higher energy efficiency. – Rapid - torque control is fast; the drive system can have a very high dynamic speed response. Jan 27, 2014 · A new 100 hp direct drive pump from OMAX Corp. 5 Web-Page: www. welchvacuum. The pump is directly connected to the engine or motor so that the rotation speed of the pump is several times that of the belt driven model. Direct drive crankshaft pumps are smaller, quieter and more efficient, but cannot dead-head, and must displace the water whenever the motor is on, which is done by dumping the water over a relief valve to drain. (We address drive arrangements in detail in a separate presentation. Hydraulic intensifiers are less expensive to maintain and last longer, but cost more upfront. 5 kw direct drive pump, as some of you already know. Direct Drive pump www. A V-drive and a direct drive are both inboard propulsion systems, which means the engine drives a propshaft that passes through the boat bottom, with the propeller positioned under the boat and steering accomplished by a rudder. This kind of pump mounts directly on the motor or engine, has few moving parts, and is the most cost-effective option. Aug 14, 2021 · T he next b road step after the direct pump-drive n p ress was the hydraulic intensifier w hich m ade i t possible to raise the pressure which cannot be achieved dir ectly by pumping action. The following text is to illustrate the respective advantages and disadvantages as well as give specific application examples of when it is advantageous to use a gearbox in an electric drive train or when a direct drive is the better choice. Jan 18, 2018 · For instance, a 60,000 psi intensifier pump at 100 pull will deliver two gallons for each moment. Two basic waterjet pumps are available - hydraulic intensifier pumps and direct drive pumps (also called crank or positive displacement pumps). ) When comparing and contrasting direct drive to belt drive fans, I think we should address efficiency, safety, reliability, maintenance, and motor replacement independently. If you have a separate generator, AC power is a rational solution, but that usually means a boat over 40 feet to justify the space, weight, and cost of a generator. Direct Drive motors are simply motors that power a system (e. May 02, 2011 · The X-Stream produces 50% more pressure than a 60,000psi intensifier pump, resulting in a 40% to 50% increase in productivity for many materials. 10 Direct torque control | Technical guide No. Delivering 30% more JetPower to the cutting head compared to the best intensifier pump designs, OMAX Direct Drive Pump Technology cuts faster, smoother, and more efficiently than any other pump technology at any pressure. 15 which means that the motor can be overloaded about 15% above current shown on its nameplate, assuming it is being operated in a normal temperature environment. The center portion of the motor is a hole completely through the center axis of the motor which allows various items such as cables, hoses, piping or even The motor most often used to drive a hydraulic pump is a 3-phase, induction-type, Design B motor. OMAX designed their Direct Drive Pump Technology to deliver the maximum cutting potential to the cutting head. Direct drive pumps are more commonly used for applications where the service time does not exceed 20 hours per week. If you are more interested in a top load option among direct drive washing machines, the LG WT7800CW is one to consider. com Printed in USA Using our proprietary tools, we can customize our direct-drive motors to fit your specifications, requirements and needs, creating an optimal drive solution for you. The intensifier delivers ultra-high pressure water to the accumulator by increasing the pressure of water received from low pressure water reservoir through water filtration unit. Magnetic Drive Pumps: Magnetic drive pumps are a type of sealless centrifugal pump. By using direction control valve, the intensifier is driven by the hydraulic unit. With low operating costs, the direct drive compressors are more cost-efficient than the belt drive compressors. Each cycle Sep 30, 2020 · Direct drive pump. 5” forged shaft with a 0% breakage rate. Also calculate the total power requirements (energy use rate). Your pumping system should be mounted in areas away from direct spray, standing water or freezing temperatures. Most direct drives stroke at over 1,000. The OMAX direct drive pump running at 60,000 psi, which does not suffer from hydraulic loss, is 85 percent efficient, delivering the A crankshaft or direct-drive style pump uses a crank to drive the pump’s plunger, while an intensifier uses a hydraulic cylinder to drive the plunger. This is what helps deliver a gentle, efficient, yet thorough clean. Get in touch with us today or call us on 1300 446 944 if you would like to know more about direct drive or belt driven air compressors. First, intensifier pumps can operate at higher pressure and have the ability to drive more than one cutting system from a single pump – a huge advantage in larger industrial applications where more than Jul 29, 2021 · An indisputable advantage of the intensifier pumps is the maximum pressure range of up to 6200 bar. The comparison: Intensifier vs. These pumps are computer optimized to fit your exact design requirements. It is a flange-mount, 3/4" shaft. From our economical direct drive pump to our fully customized units, all of our whisper-quiet mist pumps are built with high-quality components and have a proven track record of over 25 years. Power – Direct drive starters require up to 50 percent more electrical power to turn over the car’s engine than do gear reduction starters. This is a high quality economically priced, intermittent-duty pressure washer pump. But here’s a simple way of determining whether the problem is with your washer’s transmission or some other part like a clutch or a drive coupler. While it is true that direct drive pumps initially cost less, the total cost of ownership will have you paying almost double in 10 years* for a direct drive than you For example, a pump with a maximum pressure of 94,000 psi might have a nominal pressure of 90,000 psi and a continuous operating pressure of 87,000 psi. YH-H2O JET. Designed so laundry has more room to move, it drives clothes from the outer rim of the wash basket to the center, using a small amount of water to optimize the friction. Model VD Ver. Feb 26, 2019 · The direct-drive style pump uses a crank similar to the one in an automobile engine while the intensifier style drives the plunger with a hydraulic cylinder, via pressurized oil. Most systems are belt driven by a pulley or clutch, but there are also direct drive options such as direct coupled, gearbox or hollow shaft direct drive. 5 to 1. To get a more tailored look at the cost savings that can be achieved over the lifetime of an intensifier-style pump just adjust the sliders below. Efficiencies of three different pump technologies, direct drive, hydraulic intensifier, and servo drive, are compared to evaluate input electrical power and water consumption. Many so-called “oil free” pumps still contain some amounts of oil. geared rotary servomotor: A quantification of design advantage: Part 2 Testing a direct drive and geared rotary servomotor shows there are some significant differences between the two when actually put into practice. It is then directed to tubing and ends up in a storage tank. A direct drive pump cannot get up to this volume and therefore the intensifier must be the first choice for all users that want to cut especially thick or hard materials, such as titanium or thick concrete plates. The belt drive pump crankcase has a larger oil capacity. C VD(Small type) PVD VS650A VS PKS Structure Direct Drive Linear and Rotary Motors. They can be used in a wide range of products including washing machines, fans & blowers, water pumps, hydraulic pumps, ceiling fans, and industrial mixers. They can operate under the pressure between atmospheric pressure to 10Pa or lower. From left to right, top to bottom are: valve body, output shaft, pump stator, planetary gear sets, rear band, pump body and gears, direct drum, direct clutch pack, forward drum and input shaft, forward clutch hub, direct clutch hub, direct clutch pack, intermediate pressure plate, intermediate clutch pack. But the reality is that in North America, high average road speeds and hilly, even mountainous, terrain often make overdrive transmissions a more appropriate solution. Apr 07, 2014 · Here’s an exploded view of al of the components that make up a Hughes Turbo 400 build. Dec 02, 2015 · Intensifier pumps running at 90,000 psi, due to the losses from the hydraulic system, are generally under 60 percent efficient, although some of the more advanced ones can achieve efficiencies around 62 percent. Pump direct drive. A hundred drive pump at 90,000 psi will put out around 1. Use this form to estimate the brake horsepower required. Single intensifier Pump. direct drive Naturally, the question arises as to how the two drive concepts are different – or even more important, which concept is best suited for which concept, and one thing is clear: Both pump types have their reason for existence. Direct Drive Pond Pumps Direct Drive Pumps have been the mainstay of the pond and water garden industry for the last decade. Double Intensifier Pump. Direct drive pumps have less pressure variation than intensifier pumps, but either way the cut speed is set for the continuous operating pressure of the pump. Direct Drive. Dec 07, 2017 · To drive 42. ) directly without requiring a gearbox to achieve the necessary torque. Most direct drive pumps are constructed from metal and are heavier than their magnetic drive counterparts Some direct drive pump models have only single seals to protect the pump motor but most manufacturers have moved to at least double seals. Kollmorgen pioneered the development of direct drive technology. Interest in direct drive transmissions has increased in recent years, as fleets explore all available options to increase their efficiency. In traditional gearbox-operated wind turbines, the blades spin a shaft that is connected through a gearbox to the generator. Intensifier pumps are typically very inefficient, large and noisy. 67-1483R2. This reduces the heat and vibration and lessens the wear and tear associated with consistent use. com Part No. This buzzing sound was recorded from a washer that had a toothpick lodged in the pump during the wash portion of the cycle. door holders, smoke control fans, remote LED indicators, remote alarm, or trouble units. These pumps are powerful and generate a high volume of flow even when pumping to heights greater than 6-10 foot. The Patented Direct Drive Servo Technology is up to 60% more efficient than a typical Hydraulic Intensifier The superior pressure control will also ensure a constant pressure while cutting, resulting in smoother edges and less garnet being required for any given cut. YH-DDP. Oct 19, 2021 · Direct drive pump. pump, fan blades, conveyor belt, door opener, etc. Jan 28, 2013 · Direct Drive. The intensifier pump is slightly more costly but requires less maintenance and is better suited to high production rates. Pump should Jan 14, 2009 · A “Belt Drive” pump has a pulley mounted to its solid shaft and is driven by one or more belts that are attached to a pulley on the motor or engine. YH-7XD. Brake horsepower is the power out of the drive motor, and the power into the water pump and is how most pumps and drive motors are specified. Hollow bore motors are a special class of electric motor that have hollow shafts and are also known as hollow shaft and/or through shaft motors. 4. Mar 26, 2020 · Others have advocated direct-drive systems that use a mechanical crankshaft pump (see Figure 1). Rotary piston vacuum pumps are generally vee belt driven and run at about 500 rpm. Feb 28, 2017 · Intensifier vs. Many systems have traditionally used induction motors with gearboxes, mainly to achieve their cost targets, but a new proprietary brushless DC motor design Fan drive arrangements are defined by the Air Movement and Control Association International (AMCA). This means that a higher percentage of the electrical power that drives the pump actually gets to the cutting nozzle and less power is Today, both intensifier and direct drive pumps are capable of reliably delivering ultrahigh-pressure water, and both are successfully used in industry. They both have a motor, water filters, control system, and sensors, among other similarities. The water may be directly supplied to the small cylinder of the intensifier or it may be supplied through a booster pump, which typically raises the water pressure to 11 bar before supplying it to the intensifier. 1 gallons of water per minute at 55,000 PSI. The two pumps have certain components in common. Nov 24, 2014 · A belt-driven pressure washer’s pumps run on a gear reduction pulley system, allowing pumps to turn at a lower RPM (Revolutions Per Minute) than a direct drive pump. Modern abrasive waterjet machines use either an intensifier pump or direct- drive pump to generate the The comparison: Intensifier vs. It transmits the torque from the motor to the impeller by means of a rotating outer magnet which transmits the magnetic flux through a can to an inner magnet that is attached to the impeller. To help select which JD Series mixer is right for May 03, 2011 · The X-Stream produces 50% more pressure than a 60,000psi intensifier pump, resulting in a 40% to 50% increase in productivity for many materials. 1 A DC machine is able to produce a torque that is: – Direct - the motor torque is proportional to the armture current: the torque can thus be controlled directly and accurately. The overflow valve is used to adjust the limited pressure of the system and also acts as a safe overflow. Operation. The gearbox converts the turning speed of the Cat Pumps are offered with a variety of different drive options. Due to the simplicity of direct drive pumps the design is more compact which is useful when used in tight areas. This drive system has less process, simple Direct drive meaning that the pump and engine are connected directly together. x 40 = 4000 bar. Designers must remember that the efficiency of the Roots design vacuum booster is best at the higher speed, typically that of a 3600 rpm motor. Nov 22, 1991 · Other drive sources for the intensifier include high pressure hydraulic fluid from an external pump. Top Load Washer with Direct Drive - LG WT7800CW - $1,099. Basic differences being direct drive pumps will run at exact same speed as engine. Each pump has its advantages. A visual and/or audible system component that indicates an alarm or other condition. Mar 01, 2011 · Gearbox vs. The crank drive pump is quieter, uses less water and power and is more straight forward to maintain. g. The intensifier pump An indisputable advantage of the Sep 16, 2021 · The intensifier pump is not as efficient and is more costly to operate than the direct drive pump. The oil rotary vacuum pumps are the leading vacuum pumps with high pumping efficiency and consistent pumping performance. Feb 05, 2016 · So we have now an upgraded version with a 1. Jan 13, 2013 · There are basically three choices for powering the watermaker on a sailboat: AC electric power, DC electric power, and direct drive from the main engine. The direct-drive models generally run at 3600 rpm. The service factors on most open frame sizes is 0. Put the unit in spin Required Water Pump Horsepower. Direct Drive (Triplex Crankshaft) Pump Which should you buy? If you want the least frequent maintenance… Hydraulic Intensifier If you want the lowest short term expense… Direct Drive Pump When looking at Direct Drive vs Intensifier Pumps, it is important to consider the cost over the pump's lifetime. Let's take a closer look at some of the differences between a v-drive vs. soitaabusa. a direct drive engine. A belt drive will be separated by a system of belts and pullies. The hydraulic oil pump is driven by an electric motor and supplies high pressure oil from oil reservoir to drive a reciprocating plunger pump termed an intensifier. Air pressure amplifiers are also known as air boosters and air intensifiers and are used for increasing or boosting existing plant air pressures. Heavy use pressure washer applications will demand a belt-driven pump. A 50 horsepower direct drive pump can deliver about 45 horsepower to the nozzle versus a good intensifier delivering 35 horsepower to the nozzle. As we The proposed system uses seawater as the working fluid in a hydro-mechanical coupling and replaces the reverse osmosis high-pressure pump with a hydraulic converter for direct-drive, allowing for minimal intermediary power conversions, which leads to fewer parts necessary for operation and higher efficiencies. World Class technology coupled with Gold Medal Service and Support and a customer first philosophy sets Soitaab Drive- There are two kinds of drives in a typical unit: direct driven and belt-drive (which will be explained in detail in corresponding sections below) Pump- The energy created from the drive is used by a pump to draw in and pressurize the air. The distribution valve is used to change the direction of the supply liquid. The normal gasoline engine speed is about 3600rpm. Intensifier pumps have several advantages over direct drive machines that often make them a better fit for larger industrial applications. In the case where the hydraulic fluid is at pressures higher than the desired gaseous fuel injection pressure, the intensifier would be driven by the small-area piston and the gaseous fuel would be compressed by the large-area piston. But not only for do-it-yourself projects, many professionals prefer to use the direct drive compressors for other more Jul 03, 2021 · Traction drives for on- and off-road vehicles can be designed with or without a gearbox; both variants can be useful in practice. Nov 01, 2004 · Waterjet cutting works with either a mechanically driven, direct-drive pump that pressurizes water in a small cylinder with a plunger, or with a hydraulically driven intensifier that pressurizes water in a larger cylinder. -Watch the Washer Pump Repair Videos!-Buy A Washing Machine Pump! Mar 16, 2006 · See, the motor shaft sticks right into the pump so when the pump’s pumpin’, the motor’s gotta be motorin’. Nov 29, 2016 · How Pumps Work. JD Series mixers are best for mixing applications handling viscosities under 1,000 cP and handling up to 500 gallons (1,893 liters). Direct drive pumps are mechanically simpler than belt drive pumps. Using extreme pressures, it goes from a 20-to-1-compression ratio meaning that it has 20 times greater area for the hydraulic piston than the high-pressure water. 5621 W. May 05, 2011 · This means that a higher percentage of the electrical power that drives the pump actually gets to the cutting nozzle and less power is wasted as heat. For more information contact: Accu-Stream Direct Drive HP Pump • 200HP 55,000 psi crank pump Pump Motor/Engine. Thus, the fan blades will rotate at the same speed as the motor rotates. Compared to a 60,000psi pump, typical operating pressures of 75,000psi use 30% less water, 30% less power, and up to 50% less abrasive, resulting in a 40% reduction in operating costs. It has pressure ripples and is noisy, but it does have a longer seal life and is more suited to 24-hour operations using multiple independent nozzles. Maintenance. May 13, 2013 · The vee belt drive option allows the drive speed to be designed to suit the specific pump downtime specified. Nov 05, 2003 · RE: Belt Drive vs. The differences between belt drive and direct drive air compressors are well worth learning. With a 50-hp intensifier, a Jet Edge Waterjet generates 1. Today, our Direct Drive Rotary (DDR) and Direct Drive Linear (DDL) motors bring you industry-leading performance, zero maintenance, clean mechanical assembly, improved accuracy, higher throughput, better reliability, and smooth, quiet operation. 5 gallons for every moment. Jet Edge offers both styles of pumps. The intensifier pump An indisputable advantage of the Jun 08, 2011 · A crankshaft or direct-drive style pump uses a crank to drive the pump’s plunger, while an intensifier uses a hydraulic cylinder to drive the plunger. Jun 25, 2014 · Combining HyperJet® intensifier pump technology with direct-drive pump efficiency, the pump is designed to increase maintenance intervals over previous models. When operating at peak output power and efficiency, direct drive (crank shaft) pumps have an efficiency of 85]7, % [hydraulic intensifier pumps have efficiencies in the Apr 01, 2013 · A user-friendly LCD operator interface with intuitive touchpad control makes it easy for operators to adjust basic pump functions," said the spokesperson. So the capacity to drive double cutting heads by then is restricted on the 90,000 psi draw as a result of the GPM that it’s able to do. Direct Coupled Fan Drive Hydraulic Fan Drive 2500 2000 1500 1000 500 0 500 700 900 1100 1300 1500 1700 1900 2100 Power & Fuel Savings Tip Clearance Direct Fan Drive Hydraulic Fan Drive Engine Tip Clearance Reduced by 75% Engine Reduced Power Consumption, Increased Control: A hydraulic fan drive reduces tip clearance and improves airflow by 10-15%. The pump has a maximum developed pressure of 60,000 PSI and comes standard with the patented Pac-V patented control valve, which enables cutting at any pressure. Innovators in Pump Technology 2 The Sundyne direct drive pumps feature a single stage centrifugal design for reliable service in API-610 and general industrial applications. A direct drive pump uses a crank to drive the pump’s plunger, while an intensifier uses a hydraulic cylinder to drive the plunger. During the initial two decades of waterjet cutting, relatively small increments in pump pressures up to 60,000 PSI (4,100 bar) were typical; during the last decade, pump pressures jumped to pressures of 90,000 PSI (6,200 bar). Jul 15, 2011 · Energy, Power Direct-drive Wind Turbines Flex Muscles A different drive train design that eliminates the gearbox between a turbine’s rotor and generator is attracting wind turbine manufacturers in the quest for higher power output, increased offshore reliability, and potential cost savings over the system’s lifetime. Pro: Greater efficiency is the biggest pro of direct drive fan configurations. Jan 14, 2015 · Rotary vane vacuum pumps are available as direct drive (usually 1800 rpm) and vee belt drive (between 400 and 500 rpm) versions. Feb 24, 2015 · The Pump II-47 Direct Drive Pump II-47 Intensifier Pump II-47 Categories of Waterjet Cutting Machines on the Basis of Size II-48 Disadvantages of Waterjet Cutting Method II-48 Apr 18, 2019 · Pressure Amplifiers. Case study impact: Eliminating a harmful substance from the site made the direct drive option appealing due to the environmental concerns of usage, maintenance and storage. Torque can be Direct Drive pumps deliver high head and solids handling ability for the most demanding in-pond applications Brushless DC fountain pumps provide a multitude of pre-set programs, while brushless DC water garden versions adjust from low to extremely high flows for the lowest wattages ever Hollow Bore / Direct Drive / Frameless Motors. Direct Drive edison123 (Electrical) 6 Nov 03 23:15 Assuming speed reduction, a direct drive low speed motor will have a lower efficiency, lower power factor, bigger size and higher cost as compared to belt driven higher speed motor. A crank is used by the direct drive pump to drive the pump’s plunger, while a hydraulic cylinder is used by an intensifier to drive the plunger. Defined: In a direct drive configuration, the fan motor that controls the movement of the fan blades is connected either to a shaft or fan axle. In previous decades a trade-off between these technologies existed. com. They will run around 3800 RPM, advantages being they are simple, no belts to adjust, and less expensive initially. 2015 H2O JET SMP-50 WATERJET (INTENSIFIER) [WJ-010235] Manufacturer: H2O JET H2O JET 921414-CD44BA1B SMP-50 Waterjet Intensifier Pump-- Pump motor 50 HP -- Maximum water pressure 60,000 PSI -- Maximum hydraulic pressure 3,000 PSI -- Maximum flow rate 1 GPM -- Maximum orifice size 0. A washing machine with an impeller uses less motion and water than a washer with an agitator. Rotary direct drive pumps are used on over 20% of waterjet systems installed worldwide. The single acting compressed air boosters displace air once per full cycle. Intensifier VS. ” Intensifier Pump ( 420mpa and 600mpa ) and direct drive pump. Blade carrier connects to the shaft with 10 ¾” hardened bolts (no need for a stump jumper) Grease filled drive eliminates oil loss due to barbed wire cutting lower seal. Each pressure amplifier comprises a spool valve that acts as a 4-way directional control valve. DIRECT DRIVE. Dec 13, 2017 · Direct drive permanent magnet motors and drives virtually eliminate these concerns. A hydraulic intensifier is a hydraulic machine for transforming hydraulic power at low pressure into a reduced volume at higher pressure. But when extreme pressures are used, the intensifier is at 25. Intensifier Pumps We know cost is a concern - which is why we include the same intensifier style pump with the Z-Series that is used on all of our waterjets. The ZIPP Pneudraulic Intensifier is designed to operate ZIPP Rivet C-Squeezers, such as the Model Z6000C (6K force) and Model Z9000C (9K force), as well as the Model Z5000A, Z7000A, and Z9000A Alligator Squeezers. . Unlike intensifier based pumps, the direct drive rotary pump has no hydraulic pump. We are offering the new version (direct drive) for the price of the old one (air pump) : (15 000 Large Direct Drive Mixers - JD Series. The pump of this drive system provides high pressure working liquid to the hydraulic cylinder. 4 or 1. The difference in pump efficiencies means that you need 20 extra electric motor horsepower with an intensifier pump just to match the output of an OMAX pump. Howard Street Niles, IL 60714 Phone: (847) 676-8800 Fax: (847) 677-8606 (Technical Support) E-Mail: [email protected] Basic Sump and Pump arrangement Again, it's important that the intake of the pump sits at least 100mm above the base of the sump so that there's a reduced risk of sucking in any silt or detritus The Direct Drive, offered by Barber Electronics, is truly an organic overdrive. intensifier pump vs direct drive